CPE 250 - 64 kW Fast Charging
Custom Smart DC Fast Charging
Station Electrical Input
- Input Rating:
- 400V AC, 3-phase, 96A, 50 Hz
- 480V AC, 3-phase, 80A, 60 Hz
- Wiring: L1, L2, L3, Neutral & Earth
Station Electrical Output
- Max Output Power: 62.5 kW
- Output Voltage, Charging: 200–1,000V DC
- Max Output Current: 156A
- Max Modules per Station: 2
Paired Station Electrical Output
- Paired Max Output Power: 125 kW
- Paired Max Output Current:
- CCS1: 174A or 200A
- CCS2: 200A
- CHAdeMO; US: 140A, EU: 125A
Power Module
- Max Output Power: 31.25 kW
- Max Output Current: 78 A
- Power Conversion Efficiency: > 95%
- Power Factor: 0.99 at full load
- Harmonics iTHD: < 5% (Complies with IEEE 519 Requirements)
- Power Module Cooling: Liquid Cooling Technology
Functional Interfaces
- Max Connector Types per Station: Up to two different connector types per station
- Supported Connector Types: CHAdeMO, CCS1 (SAE J1772™ Combo), CCS2 (IEC 61851-23)
- Cable Length with Swing Arm: Full Horizontal Reach: 4.27m (14’)
- LCD Display: Full-color 254 mm (10 in) display for driver interaction
- Top Display: Full-color 508 mm (20 in) LED display for notifications
- Authentication:
- RFID: ISO 15693, ISO 14443, NEMA EVSE 1.2-2015 (UR)
- Tap to Charge (NFC on Apple & Android): 15118-1 (EIM)
- Remote: Mobile and in vehicle (if supported by vehicle)
Connectivity Features
- Vehicle Safety Communication: CHAdeMO – JEVS G104 over CAN, CCS1 – SAE J1772 over PLC, and CCS2 — IEC 61851-23
- Plug-Out Detection: Power terminated per JEVS G104 (CHAdeMO), SAE J2931 (CCS1) and IEC 61851-23 (CCS2)
- Local Area Network: 2.4 GHz and 5 GHz WiFi (802.11 b/g/n)
- Wide Area Network: 4G LTE (fall back to 3G GSM)
- Supported Communication Protocols: OCPP
- Service and Maintenance: Remote system monitoring, diagnostic, and proactive maintenance
Safety and Operational Ratings
- Station Enclosure Rating: Type 3R, IP54
- Station Impact Rating: IK10
- Safety and Compliance: UL and cUL listed: complies with UL 2202, UL 2231-1, UL 2231-2, CSA 107.1; CE marking: complies with IEC 62196, IEC 61851
- Station Surge Protection: Tested to IEC 6100-4-5, Level 5 (6 kV @ 3,000A). In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended.
- EMC Compliance: U.S.: FCC part 15 Class A; EU: EN55011
Environmental and Operational Conditions
- Cooling: Liquid Cooling Technology
- Storage Temperature: -40°C to 50°C (-40°F to 122°F)
- Operating Temperature: -40°C to 50°C (-40°F to 122°F)
- Operational Altitude: Less than 3,000 m (Less than 9,800 ft)
- Operating Humidity: Up to 95% @ 50°C (122°F) non-condensing
Generic Specifications
- Station Enclosure Dimensions: 2,230 mm x 712 mm x 420 mm (7'4" x 2'4" x 1'4")
- Power Module Dimensions: 760 mm x 430 mm x 130 mm (2'6" x 1'5" x 5")
- Station Weight (without Power Modules): 250 kg (551 lb)
- Power Module Weight: 45 kg (98.5 lb)
Energy Management Features
- Dynamic Power Management: Allows a fixed maximum power output per station or lets the system dynamically manage the power distribution per station.
- Remote Energy Management: Manage output power via the ChargePoint Admin Portal, API, and Open ADR 2.0b VEN.